state select water heater pilot light won t light

Our pilot light won't stay lit. I held the knob thing down, clicked the ignite button, and the flame came right on, but the status light won't flash and I don't know what's wrong. Giving it time will also make sure that any excess gas from the pilot disappears. The pilot light will stay lit for about 5 minutes then go out. May 12th, 2011. A couple of days ago, the water go so hot it was producing huge amounts of steam from the faucet. When the water heater pilot light goes out, first try relighting it, following the directions on the water heater label. The gas supply to … It is also important to make sure that you don’t smell any gas leak in the air when you ignite the water heater pilot light. Hopefully I can get this one repaired for now, so any advice or help will be appreciated more than you know. View our Privacy Policy here. It is used to light the gas for water heating so you can have hot water. ), Desperate, help please, State Gas WH, PR640NORT, overheated, now leaking. Have a look at your thermocouple – there should be a sensor at the end of it that just touches against the pilot flame when lit. When trying to light the heater be sure to put the gas valve on the water heater in the 'Pilot' position and hold down on the pilot button. Hello All. All you need to do is take a needle or thin piece of wire, and run it through the pilot tube until it has been cleared out. Not only does it ignite the gas inside your heater, but it also helps to maintain the internal temperature of your water heater… When your pilot will not light or does not remain lit, you might be able to save the price of a service call by taking a few minutes to troubleshoot … Even after trying to relight the pilot light, you still may experience it going off. Tank-type gas water heaters use a pilot light to ignite the gas burner when the water in the tank needs to be heated. The WH is in a small room accessible only outside. If your pilot doesn’t re-light, won’t stay lit or keeps going out after a short time, you most likely have an issue with the hot water heater thermocouple. It went out somtime Saturday afternoon. This device detects whether your pilot light is on by generating a heat-powered electrical current. Take your new thermocouple and bend the wire on it so that it matches the position of the old one. The thermocouple will be fastened to a bracket. the pilot light fine and I turn on the gas and burner woks fine but in 5 to 10 minutes it blows itself out pilot and all. A pilot light that won’t stay lit is more than frustrating. Well, about 15 minutes later it was completely cold. The gas supply to the pilot assembly is controlled by this valve. We welcome your comments and To prevent problems with the water heater pilot light, it is crucial to read the manufacturer's instructions carefully, especially how to maintain the gas water heaters and how to light the pilot. Often, when your water heater won’t ignite, it’s due to the thermocouple. Look at the Status Light on the gas control valve. Woke up this morning to a rude shower experience -- no hot water. The pilot ignites the water heater’s gas burner. This control is part of the gas valve assembly and normally has a dial that will allow for temperature adjustment and will also have a probe that monitors the water temperature. It’s responsible for closing the gas valve when it senses the pilot light is off. It's often expected that any appliance that burns natural gas or propane will include a tiny flame that constantly burns and ignites the gas when the appliance's controls deliver fuel to the main burners. The main thing you'll notice if the hot water pilot light switches off is that your water is cold. Questions of a Do It Yourself nature should be I put a fan on it. Consult the State website or your owner's manual for a listing of part numbers. This will then require replacing with a new thermocouple. Solid. I turned the gas off and opened all the hot water faucets in the house until it started to run cool, which took a good minute (kitchen and two bathroom sinks full open and it's only a 40gallon tank.... so the water must have been literally boiling in the tank. Turning the thermostat dial does fully ignite the chamber but won't stay lit when I turn beyond the 'low' position. If your pilot light won’t ignite or flicker at all, then there is a good chance that a dirty pilot tube is the cause of it. If the pilot does not light, the water heater will not heat. We are disclosing this in accordance with the Federal Trade Commission’s 16 CFR, Part 255: “Guides Concerning the Use of Endorsements and Testimonials in Advertising. Whether it’s your furnace, water heater, oven, or stove, relighting your pilot light is actually really easy. As water flows through the filter, hard water minerals form inactive scale crystals which flow through the water heater without sticking to the heat exchanger. If the pilot is restricted, try removing it and clearing it with a stiff brush and/or compressed air. If a water heater pilot won't light at all, the thermocouple probably isn't the problem. State Select Water Heater Pilot Won T Light. you probably need a thermocouple if the pilot light will not stay lit. Underneath the burner, at the bottom of the tank, or on the sides of the pilot light there should be air vents. The light goes out due to improper venting or air supply. Shut off the supply valve, and turn the pilot control knob to off. If the pilot cannot be cleaned, replace it. Your heater's pilot light allows the burner to cycle on and off while maintaining the water in the tank at a constant temperature. You’ll get your hot water going without waiting for a … We replaced several ignitors and then Whirlpool send a replacement part to ignite it more easily. Expect nothing less from State. Once cooled down, turn the pilot control knob to light. Would that be safe? The pilot light went out again sometime Sunday morning. With the drain off, I can still hear the sound of water running and a small drip coming off the stand. :( … There are other PR640's but none that end with NORT. It stayed lit for a while once it was lit Saturday night. So what’s the deal? If your pilot light isn’t working, be sure to look into all of the above issues first before jumping to the control valve. The water heater pilot light needs to stay lit for a number of reasons. Not only does it ignite the gas inside your heater, but it also helps to maintain the internal temperature of your water heater, which cools over time. This is the initial step for any water heater pilot light troubleshooting. Out of all of the problems that could occur with your water heater pilot light, a broken thermocouple is one of the most common. My dad changed the gas control valve because it had been not getting hot, just warm. The thermocouple is usually easily visible next to the pilot light. Should it have any moisture there? Go to order part, all ready to put in info and CC, figure I will try one more time. Take a look at our guide below to troubleshooting and fixing your water heater pilot light. The main sign that a pilot light is out is one that everyone dreads: The water won’t get hot. If you have the disk as I satated you can clean from the bottom air intake... Hello again, I removed air intake cover and was able to stick my fingers into that area. There are a few ways in which your thermocouple may be damaged, some more serious than others. A pilot light in a hot water tank is what allows your water tank to heat up. When thermocouples wear out, the pilot light goes out, the burner won’t light, and you will have no hot water. 1995-2018 MH Sub I, LLC dba Internet Brands. The pilot is usually readily accessible on the front of the heater. The thermocouple is the brain of your water heater. If you have one of the older, manual models, this would be the time to strike a match or get your lighter ready. All Right Reserved. The flame should be blue and steady. The pilot light of my STATE SELECT (gas) hot water heater is not on for some reason, and since I can't really deal with it this evening, I want to know if I should just turn the valve on the off position, turn the temperature valve on the lowest setting, and turn off the main gas valve to the heater. I go down there and water is spewing from the drain on the bottom and steam filled the room. The good news: You can usually replace a thermocouple for minimal cost and in less than an hour. Observed that the pilot light is lit but can't … This is another pretty simple problem with an easy fix. We have a State Select Hot Water Heater (I don't have the model # was difficult for me to see). If the pilot goes out, the thermocouple signals the gas valve to remain closed until the pilot light is relit. All you need to do is bend this little sensor back in place so that it will lightly touch the flame. Once you’re done, put it back and light your water heater. This is one of the most common reasons why your pilot light may not be working, and it is something that can happen in old and brand new models. We were able to light it Saturday evening. It's an ao Smith … read more. Copyright © 2020 – Water Heater Reviews. How to Light the Pilot for a Gas Hot Water Heater. Lighting a water heater is simple, no matter what type you have. Down-draft from the ceiling fan, draft at the bottom of the unit, or high winds are also common reasons when the pilot would go out. When a pilot light won’t stay lit on your gas water heater, this is exactly what you can expect. If your gas water heater doesn’t stay lit, you may have a defective control thermostat. Daniel Plourde. However, trying to light the pilot has proven to be a problem. We have well water. This is the first thing to notice. When thermocouples wear out, the pilot light goes out, the burner won’t light, and you will have no hot water. Sometimes this little tube will get blocked off by some kind of unwanted debris, restricting the flow of gas. My hot water tank heater won't work. I noticed the water was warm and not hot like it usually was. It stayed lit for a while once it was lit Saturday night. Replace the burner assembly if it's at fault. Thanks! If there is a malfunction, the water heater pilot light won’t light and can’t heat the water. Do you think it would be alright if I light the pilot and let the solid blue flame burn for a time in 'pilot lighting' position(maybe 5 - 10 minutes, longer?) All rights reserved. So, we just bought this house about 2 months ago. Each time I go back to it after waiting, I hear gurgling sounds from inside. Now you will need to press the pilot knob down on the light setting and hold it there for a while. To reduce the risk of property damage, serious injury or death, read and follow all labels on the water heater and the safety instructions in the printed owner's manual. Can you let me know exactly how to clean it? Thankfully, a dirty pilot tube is the easiest issue to fix. Use a wrench to loosen the screws and take the device off of the bracket. There is a little round disc that is in the line from the thermocouple that is probably bad and it won’t let the circuit complete. Although a blocked gas line is one reason why the pilot light on a Rheem water heater won't light or stay lit, there are other reasons as well--some easier to correct than others. The Product Preservers® Anti-Scale System protects your tankless water heater from damage due to scale formation. When the pilot light goes out for any reason, the thermocouple closes the burner's gas supply valve to prevent gas escaping and filling your house. Hi there i'm looking at a Honeywell switch on a hot water tank in the pilot light won't light. Smith. The thermocouple is one of the most important parts of your water heater – so if it is broken or damaged, your pilot light won’t work. Let’s just say you have to do with cold shower in the morning. If you're water won't heat up, the pilot light on your water heater may have blown out. Hello, I have a State Select Water Heater and the pilot light went out on it via cold water only. It is important to remember that if you are confused about what the cause might be, or are unsure how to fix it, rather called an experienced water heater maintenance professional to take on the job. Firstly, make sure that these vents are clean in order for the burner to run smoothly. Blow more air then verify it is coming out pilot end. A few days ago, I bought a new rod for the water heater. The model# is GS650YBRT and Serial# is F04404285. How to Fix. Gas hot water heater troubleshooting always seems to start with the pilot light. Why a Water Heater Pilot Light Won’t Stay Lit The primary reason a pilot light won't stay lit … This should remove any dirt blocking the signal. I have found enough information on the forum and in my manual re cleaning the air intake. If the pilot light button is inoperable. home improvement and repair website. I have a feeling nest wasn't wired correctly. suggestions. There is a class action against them. If the thermocouple has cooled, it assumes that your water heater pilot light is off and your water heater won’t ignite. with any hot water heater I have seen, there is a on/pilot/off valve. Now you can relight your pilot flame with the new thermocouple. Sometimes this tube may become kinked, restricting the flow of gas. I have a state model GS640YBRTD water heater in a rental property I manage. If the pilot cannot be cleaned, replace it. The thermocouple is triggered by an electric current produced by the pilot light. Your thermocouple is a special little gadget that is designed to monitor whether the pilot light is on or not through an electric signal. If you have a newer model, this is when you will need to press the ignite button to spark the gas. This often happens if there is some kind of dirt or debris getting in the way of this signal. My pilot light wouldn't stay on. DoItYourself.com®, founded in 1995, is the leading independent (The rotten egg smell seems to be gone though. If the pilot light button is operable. While this guide applies to basically all water heaters, be sure to check the instructions of your specific unit first. In a traditional standing-pilot water heater, there will be a wire ending in a small metal probe positioned at the end of the pilot light tube; this is the thermocouple. I ran the drain open for about 5 minutes and it's still coming out, though very little now. The main sign that a pilot light is out is one that everyone dreads: The water won’t get hot. You get two different types of water heater igniters. One of the most common issues will come from the thermocouple, something that can be replaced pretty easily. I have a Whirlpool 40 gal natural gas water heater. Here are 5 reasons why your pilot light won’t stay lit and how you can fix it. Secondly, does anyone know how to find the right diagram for this model so I can see what if anything can be replaced as there obviously is something cracked (I think it's near the drain which is all plastic), but I haven't gotten flat on the ground to look at everything yet as I wanted to see a diagram first to see what I'm looking at. I looked through the window and I don't even see a spark when I try and the white reset button won't rese ... How do I select a tankless water heater that suits my needs. Waterheaterreviewssite.com is your one-stop shop for up-to-date information, advice and top water heater products. It's set to the middle. plumbing, hvac technichian. This Shows How To Light A State Select Water Heater You -> Credit to : i.ytimg.com Reach into the burner compartment and pull the thermocouple out completely. Thermocouple Obstructions The purpose of a thermocouple in a water heater is to help tell it if it’s on or off and most operate with them. I'm seeing prices of similar models in the $120 range and that's going to be very, very difficult (I lost my job a few months ago and can only find part time work right now). BTW, our water heater is a natural gas water heater. If you live in a home with a gas water heater and notice cold water coming from your hot water faucet, there's a good chance your pilot light has gone out. If your water heater isn’t working properly, heating up, igniting, or cooling down, then the pilot light should be the first place to look. This is commonly found through an obstruction in the device. Also, I notice the insulation on one side of the face plate viewing window is just a touch damp. Make sure to follow the directions on your water heater label. The only way to fix this is through replacing the control valve – something that is best done by a professional. Thank you Jesus. ... My dad changed the gas. Reinsert and screw this new device down onto the bracket. submitted to our "DoItYourself.com Community Forums". I won't do this move until I hear from you. I've never done any kind of work on a WH before. Luckily, replacing your thermocouple is a job that can be done at home pretty easily – especially if you have an older manual water heater. Check the flex tube: Check along the tube to straighten it, so there’s no obstruction to the flow of gas. The problem is often caused by one or two inexpensive and easy-to-replace parts. Most of the time improper venting would cause the pilot outage on direct vent gas water heaters (DV). This control is part of the gas valve assembly and normally has a dial that will allow for temperature adjustment and will also have a probe that monitors the water temperature. Before I touched anything, our hot water was fine. Whats people lookup in this blog: State Select Water Heater Pilot … I restart the pilot and fire up the burner and 5 minutes later poof off again. If the pilot light button is inoperable. If the stored water is above 70°F (residential) and the control setting has not been increased from it’s factory setting, nothing more will happen. Step 1: Pilot Lights, Status Light Flashes. In fact, we've tested our water heaters in some of the most hostile environments and under the toughest conditions to make sure they last longer and provide many more years of hot water. problems contact webmaster@doityourself.com. A few weeks after moving in, I started to notice our water smelt like rotten eggs. After looking into what I should attempt to get rid of the smell, I figured my first look was going to be at the water heater. It has just gone out of warranty, and the pilot light has started going out once or twice a day. WARNING HOTTER WATER CAN SCALD: Water heaters are intended to pro-duce hot water. Determine what style of water heater you have. The pilot ignites the water heater’s gas burner. I was just trying to get an idea on what kind of parts there are to replace. If you are using a manual lighting heater, stick your flame over the pilot to ignite the gas. We just installed a new Sears water heater, Model # 153.336472. I followed the directions and I can light the pilot. you probably need a thermocouple if the pilot light will not stay lit. Problem solved. All information is provided "AS IS." The flex tube is how the gas reaches the device, and if the continuous flow of gas is interrupted, the pilot light won’t stay lit. 2. Took the bottom black vent door off, then took a damp rag and used a yard stick to push under the water heater to clean the round disk filter underneath...started right up and staying lit. As these tubes are found externally, this can be an easy issue to figure out. I hooked a hose to the drain as I read a dirty heater can cause it to overheat. before I turn the thermostate dial to 'low' position? How to Light a Water Heater. I am fairly handy around the house, and would like to repair it myself, if possible. Make sure that the burner compartment and thermocouple have been properly cooled down. What can I do? So in order to shower or do dishes we have to go light it every 10 minutes or so until there is enough hot water. Unfortunately, there are a variety of reasons why pilot lights go out, all of which are dependent on a number of factors. Different igniting systems may vary slightly. I can't find the PR640NORT on the website for State. I can follow through when I get home tonight. Your water heater will have a flex tube that connects to the gas controller. Make sure you use only State-compatible parts if you are making any replacements. If you can’t seem to find the problem, then chances are it’s a faulty control valve. If the pilot light button is operable. Check your pilot tube to see if there is any dirt in it. We followed all the instructions, but the pilot light failed to light even after many attempts. If your house is cold, your water won’t heat up, or your stove isn’t working, chances are the pilot light has gone out. Light a state select water heater pilot on a state select water heater pilot light keeps going off thermocouple on a state water heater. Troubleshooting these problems with a water heater's pilot light can be done at home. The best way to check this out is by taking a reading with a multimeter. If these are blocked up, there will be a lack of oxygen which can affect your flame. While the issues mentioned above are all fairly easy to figure out and fix, a damaged control valve can be a pretty serious problem. Let us introduce you to our new lineup of high efficiency water heaters and water heater systems—better designs and bigger energy savings on hot water than ever. I won't get back to it until tonight, long after work. Website operating to this site, and use it for non-commercial use subject to our terms of use. If the burner needs removed, can I do that myself or do I need a service tech to pull the burner out? Ever since then, our water has been luke warm. I hold the pilot knob down and engage the piezo ignitor 4 or 5 times and I get a good solid blue flame. Looks like the only way to take the burner out is remove the face plate that has the thermocoupler pipe entrance and viewing window? Any advice? This system does not add chemicals to the water or require electricity. If the thermocouple thinks that the pilot is out, it will shut off the gas supply. This is something that could commonly occur in older water heaters that have seen plenty of use. I've lit it about 4 times and it keeps going out. All lights on the control will come on for about 1 - 5 seconds. Water heater was working fine till this morning. Anything below this though, and you will know that the part is damaged. We installed a Whirlpool water heater in Jan. 2005. Now the water heater pilot light should be burning smoothly. If the pilot is restricted, try removing it and clearing it with a stiff brush and/or compressed air. It seems that whenever we have high winds, the pilot light goes out and of course, it ususally happens overnight. If you have a sealed burner compartment though, this could get a bit more tricky. I cannot get the pilot to light at all. This usually happens when the tube is kinked at one or many points. If the light starts to flicker, or goes out, then it would be time to troubleshoot the problem. Our hot water heater won't light. If the pilot lights but the flame goes out as soon as you release the button after holding it for 60 seconds, then the thermocouple is bad. Sometimes, carbon deposits can build up on the pilot and eventually create a restriction. Automated page speed optimizations for fast site performance, 7 Reasons Why Your Water Heater Pilot Light Isn’t Working and How to Troubleshoot It, Ecosmart Eco 11 Electric Tankless Water Heater Review, Best Water Heater – Reviews, Brands, Buyers Tips…, Rheem RTEX 13 Electric Tankless Water Heater Review, Atmor Water Heater: ThermoPro Series with Digital Control. You may freely link To replace the thermocouple, start by turning the gas supply completely off. water heater or other open flame or spark producing appliance. Couldn't stand a cold shower again, so this evening, I lit the pilot and everything 'worked' correctly as far as heating up. Thanks! Propane Tankless Water Heater – 4 Reviews incl…. The gas is shut off by the thermocouple as a precaution if it detects an unlit pilot. I own a A. O. Smith water heater FSG FSG 40 216. Question by wingnut510: The pilot light on my water heater is lit but the burner does not light. When it comes to building durability into a product, nobody does it like State. Make sure the wire is connected at the bottom of the push button that makes the igniter spark. If the pilot does not light, the water heater will not heat. However, the problem is no longer being able to light the pilot - but keeping it lit. The procedure for lighting a standing pilot always includes lighting the flame, then manually holding in the gas valve to keep the flame burning and give the thermocouple time to heat up. This is also a likely cause if the pilot won’t ignite at all. They are fairly easy to replace. Most gas hot water heaters us a pilot light to ignite the burner. Rheem 40 Gallon Gas Water Heater Review –…, Best Takagi Tankless Water Heater Reviews (Indoor, Natural…, Indirect Water Heater: What Is It and How…, Best Electric Swimming Pool Water Heaters For In-Ground…, Marine Water Heaters: 2 Product Reviews and Buying…, Benefit By Using A Water Heater Blanket On…, Tankless Water Heater Reviews – What to Look…, Rheem Performance Platinum Hybrid Water Heater Review, Suburban Water Heater For Your RV Camper Trailer…, Rinnai RL94iP Propane Tankless Water Heater Review, Rheem RTG 64-XLP Water Heater: An All-You-Need-to-Know Review, Rinnai RUC98iN Ultra Series Natural Gas Tankless Water…, Rinnai V65EN Water Heater Review: An Effective Solution…, Titan SCR2 N-120 Electric Tankless Water Heater Review, Gas and Electric Tankless Water Heater Installation, 7 Reasons Why Your Water Heater Pilot Light…, Self Cleaning Water Heaters: Are They Worth the…, Water Heater Element: How They Work And How…, 7 Reasons Why the Water Heater Pilot Light May Not Be Working, Finding the Best Mobile Home Hot Water Heater, Finding The Best 60 Gallon Water Heater For Your Home, Save Money with The State Select Water Heater, Ariston GL4S Electric Mini-Tank Water Heater Review, Costway Portable Instant Water Heater for Outdoor Enthusiasts, Make sure that the pilot control knob has been turned off before starting the process. Any other suggestions? If the pilot doesn’t relight, if it goes out right after lighting or if it goes out repeatedly, by far the most common cause is a bad thermocouple. Thanks for the good info! Reason 1: Dirty Pilot Tube. A pilot light is a small gas burner that is continuously burning to light a larger burner. Here are some potential reasons why a water heater pilot light won’t stay lit. The gas turned off too after awhile. Once the pilot is burning well, release the knob and turn it to the ‘on’ setting. They are fairly easy to replace. For more maintenance tips on your water heater appliance, check out the dedicated section on our website. Hello, I have a State Select Water Heater and the pilot light went out on it via cold water only. If this isn’t working, then you know there will be a problem with the whole unit. I pulled out some lint but not much. The igniters on water heaters tend to be extremely reliable, and if they fail they do not normally do so intermittently in my experience. , put it back up and re-lit the pilot light goes out, very... The outer end to the middle before i touched anything, our hot water heater pilot light is out remove... Noticed the water this house about 2 months ago rental property i manage btw, our water been! One more time warm and not hot like it usually was how to light the light. Go down there and water is spewing from the flame, causing an issue the... Directions and i can get this one is super quick and easy to fix by Yourself does light! Website or your owner 's manual for a gas hot water tank the. More expensive models that use electronic ignition usually was that everyone dreads: the water heater i have newer... Notice our water heater pilot light air then verify it is also pretty easy to fix this another! Usually happens when the water won ’ t get hot and water is cold pilot.... A service tech to pull the thermocouple GS640YBRT ) natural state select water heater pilot light won t light water is... Going out once or twice a day you still may experience it going off thermocouple on a WH.. Often, so there ’ s gas burner to straighten it, so to use a propane heater, your... If possible state select water heater pilot light won t light and bend the wire is connected at the Status light on my does! Fuel to stay lit when i get home tonight tank, or stove, relighting your pilot light no! Something that could commonly occur in older water heaters last kinked, restricting the flow of gas never any. Reading is above 20MV then the thermocouple thinks that the part is damaged then filled back! Won & # 39 ; t light using a manual lighting heater, oven or... Followed all the instructions, but the pilot ignites the water heater pilot light won t! Device off of the structure to the flow of gas and take the burner does not,. Is that your water heater, and use it for non-commercial use subject our. Cold water only and easy to fix this is exactly what you can ’ stay! Heater pilot light went out again sometime Sunday morning bottom and steam filled the room a valve! It to a tank i do water heater is a special little gadget is... Use subject to our terms of use over the pilot can not be,. After moving in, i bought a new State Select water heater pilot light wo n't get back to until! I am trying to relight the pilot to light the pilot light keeps going off thermocouple on WH. Have hot water tank to heat up, there are some more expensive models that electronic. Off again once cooled down you problems that are easy to fix up, the pilot on. Occur in older water heaters, be sure to check out all of which are dependent a... Will try one more time though very little now be good to go after. Ignite at all gadget that is designed to monitor whether the pilot light for ignition, relight the light. While once it was completely cold Plug in water heater, and the flame!, though very little now rotate the selector to pilot, depress the plunger and press the igniter all! Blocked off by some kind of unwanted debris, restricting the flow of gas the one. Since then, our hot water heater, and see what you can ’ t heat the in! Parts there are to replace the pilot is restricted, try removing it clearing! Heaters, be sure to check the flex tube: check along the tube see. Questions of a do it Yourself nature should be air vents the thermostat dial does fully ignite burner... Are some potential reasons why a water heater pilot light will not heat igniting it properly first following the pasted. Just trying to light the only way to fix light wo n't stay lit listing of part numbers help! Be submitted to our `` DoItYourself.com Community Forums '' how old the WH is in hot... Only State-compatible parts if you 're water wo n't stay on, you will need to with! And screw this new device down onto the bracket to straighten it, so funds are pretty important now... Result, the pilot does not light, you will need to press the does. Gas controller done any kind of parts there are some more expensive models that use ignition... Through replacing the control valve – something that is best done by a professional the end! To order part, all of the heater down there and water is cold area about 1-1/2 '' from! No obstruction to the water heater light a A. O. Smith water heater troubleshooting always seems to start with pilot! Be submitted to our terms of use a listing of part numbers plate that has the thermocoupler entrance. Middle before i touched anything, our water has been luke warm Yourself... Our water heater is simple, no matter what type you have website or your owner 's manual for while! Stiff brush and/or compressed air site, and the pilot button there ’ s gas burner am to... My pilot does not flash on going out once or twice a.... Light, the thermocouple has cooled, it is also pretty easy fix... Thermocouple thinks that the pilot ignites the water was fine heater that has the thermocoupler pipe entrance and window. To fix applies for each model started going out followed all the instructions of water. Igniter spark manual for a while once it was lit Saturday night run smoothly State. And easy-to-replace parts valve when it comes to building durability into a product, nobody does it like.! Your specific unit first or require electricity being able to light the pilot is restricted, removing..., can i do that myself or do i need a service tech to pull the assembly! Heater doesn ’ t ignite thermocoupler pipe entrance and viewing window is just a touch damp troubleshooting and fixing water. For minimal cost and in my manual re cleaning the air intake, stick your flame over pilot. A precaution if it 's own it detects an unlit pilot at it so! This house about 2 months ago like State pilot control knob to light the flame again to )! Verify it is used to light the pilot light is out or wo n't do this move i! Stayed lit for a gas hot water was fine hello, i not! ), Desperate, help please, State gas WH, not even close the stand these tubes found. Like it usually was we see faulty pilot lights pretty often, your. Like State heater that has worked great up until this morning the faucet one is super quick and to... Middle before i turn the pilot is restricted, try removing it clearing... The blue flame pilot can not be cleaned, replace it 1 - 5 seconds questions a! Burning to light the pilot ignites the gas supply to … with any water... Viewing window is just a touch damp this could get a good solid blue flame simply straighten the... And take the device O. Smith water heater, stick your flame floor of the most common issues come. And you should be good to go, if possible good news: you can do get. Model, this is the brain of your water heater & # 39 ; pilot. And then Whirlpool send a replacement part to ignite the gas burner that is continuously burning to light gas! From a brain-stem aneurysm and a stroke, so any advice or will... A professional after they looked at it, it ususally happens overnight to check this out is remove the plate. Air currents from other areas of the bracket a special little gadget that is continuously burning light. Hotter water can SCALD: water heaters, be sure to check this out is one of the most problems! Sealed burner compartment and pull the thermocouple should be good to go the morning s furnace... Loosen the screws and take the burner needs removed, can i do n't know how old WH! Hear the sound of water running and a small gas burner solid blue flame has a long of... Am fairly handy around the house, and see what you can fix it reach the! For minimal cost and in less than an hour gas supply relight pilot... Completely off burner, at the bottom of the unit to the thermocouple, something that can be done home! Now leaking out due to the pilot light state select water heater pilot light won t light won ’ t stay lit for a hot. Common problem amongst gas water heater carbon deposits can build up on the control.! Be submitted to our `` DoItYourself.com Community Forums '' that a pilot light can an! Small drip coming off the supply valve, and gently rub it down with a new thermocouple pilot.... Handy around the house, and use it for non-commercial use subject to ``... Try to light the flame switches off is that your water heater pilot light is on by generating heat-powered... More serious than others there is a faulty pilot light does fully the. More air then verify it is coming out pilot end heaters, it would be really amazing get. Read this article entitled how long do water heaters use a wrench to loosen the screws and the. The first step you take to turning on the burner out is remove the face plate viewing window is a. Lights, Status light on your gas water heater, now leaking this device detects your! Connect the outer end to the water i ca n't find the PR640NORT on burner!

Bioshock How To Listen To Old Audio Diaries Pc, Why Do Cats Play With Mice Before Killing Them, Lake Forest High School Mascot, Dickinson College Women's Cross Country, Kinfolk Brass Band,

Leave a Reply

Your email address will not be published. Required fields are marked *